Comparison of various robust and efficient load-flow techniques based on Runge–Kutta formulas

dc.contributor.authorTostado-Véliz, Marcos
dc.contributor.authorKamel, Salah
dc.contributor.authorJurado-Melguizo, Francisco
dc.date.accessioned2024-06-03T08:24:33Z
dc.date.available2024-06-03T08:24:33Z
dc.date.issued2019-09
dc.description.abstractBased on Continuous Newton’s method, any well-assessed numerical scheme can be adapted for solving the Load-Flow (LF) problem. So far, LF techniques based on 4th order Runge–Kutta formula (RK4) and Adams–Bashfort’s methods (AB) have been proposed. However, there is a huge variety of numerical methods whose adequacy for solving the LF problem has not been explored yet. This paper tries to fill this gap by proposing several LF solvers based on Runge–Kutta (RK) formulas. Thus, several LF techniques based on Midpoint (MP), 3rd order Heun (H3), Simpson 3/8 (S3/8) and an accelerated 3rd order Runge–Kutta (ARK3) formulas are proposed. The performance of the proposed LF techniques is assessed using several medium and large-scale ill-conditioned power systems. The proposed techniques are compared with RK4, AB and other robust LF methods. In addition, their scalability and influence of the loading level are analyzed. The obtained results prove that the proposed LF techniques are faster than RK4 and robust enough to successfully tackle medium and large-scale ill-conditioned power systems. As main conclusion, it is proved that lower order methods might be as robust as higher order ones but more efficient. Therefore, its usage with respect higher order methods (e.g. 4th order ones), should be frequently preferable.es_ES
dc.identifier.citationMarcos Tostado-Véliz, Salah Kamel, Francisco Jurado, Comparison of various robust and efficient load-flow techniques based on Runge–Kutta formulas, Electric Power Systems Research, Volume 174, 2019, 105881, ISSN 0378-7796, https://doi.org/10.1016/j.epsr.2019.105881.es_ES
dc.identifier.issn0378-7796es_ES
dc.identifier.other10.1016/j.epsr.2019.105881es_ES
dc.identifier.urihttps://www.sciencedirect.com/science/article/pii/S0378779619302007?via%3Dihubes_ES
dc.identifier.urihttps://hdl.handle.net/10953/2859
dc.language.isoenges_ES
dc.publisherElsevieres_ES
dc.relation.ispartofElectric Power Systems Research [2019]; [174]: [105881]es_ES
dc.rights.accessRightsinfo:eu-repo/semantics/openAccesses_ES
dc.subjectLoad flowes_ES
dc.subjectIll-conditioned power systemses_ES
dc.subjectRunge-Kutta formulases_ES
dc.subjectRobust methodses_ES
dc.titleComparison of various robust and efficient load-flow techniques based on Runge–Kutta formulases_ES
dc.typeinfo:eu-repo/semantics/articlees_ES
dc.type.versioninfo:eu-repo/semantics/acceptedVersiones_ES

Archivos

Bloque original

Mostrando 1 - 1 de 1
No hay miniatura disponible
Nombre:
Revised Paper.docx
Tamaño:
151.33 KB
Formato:
Microsoft Word XML
Descripción:

Bloque de licencias

Mostrando 1 - 1 de 1
No hay miniatura disponible
Nombre:
license.txt
Tamaño:
1.98 KB
Formato:
Item-specific license agreed upon to submission
Descripción:

Colecciones