Electrical consequences of large-scale replacement of metal halide by LED luminaires
dc.contributor.author | Hermoso Orzáez, Manuel Jesús | |
dc.contributor.author | Rojas Sola, José Ignacio | |
dc.contributor.author | Gago Calderón, Alfonso | |
dc.date.accessioned | 2023-12-07T10:39:52Z | |
dc.date.available | 2023-12-07T10:39:52Z | |
dc.date.issued | 2016-05-04 | |
dc.description.abstract | The recent trend for large-scale replacement of luminaires using discharge light sources with LED luminaires without any significant adjustments to the electrical installation has generated controversy. This study examines the main electrical measures in a large outdoor lighting installation before and after the replacement of a large number of metal halide floodlights with LED luminaires. The electrical parameters of both technologies are discussed in detail and compared, with special attention given to the odd-numbered harmonics of voltage and current, the generated wave deformation, currents in the neutral conductor, the wattless reactive volt amps and the peak inrush currents. At cold start-up, the LED luminaires generate large power-on currents, much larger than those generated by the metal halide lamps, despite requiring 36% less real installed power. This is a basic problem to be solved when planning a public lighting renovation with LED luminaires as the rest of electrical parameters are reduced. To address this problem, it is proposed to energise the luminaires using magneto-thermal protection circuits with slow trip curves that will tolerate the large short-term inrush currents. | es_ES |
dc.identifier.citation | Hermoso-Orzáez, MJ; Rojas-Sola, JI; Gago-Calderón, A. Electrical consequences of large-scale replacement of metal halide by LED luminaires. Lighting Res. Technol. 2018; 50: 282–293. DOI: https://doi.org/10.1177/1477153516645 | es_ES |
dc.identifier.issn | 1477-1535 | es_ES |
dc.identifier.other | https://doi.org/10.1177/1477153516645647 | es_ES |
dc.identifier.uri | https://journals.sagepub.com/doi/10.1177/1477153516645647 | es_ES |
dc.identifier.uri | https://hdl.handle.net/10953/1353 | |
dc.language.iso | eng | es_ES |
dc.publisher | SAGE Publications LTD | es_ES |
dc.relation.ispartof | Lighting Research & Technology | es_ES |
dc.rights | Atribución-NoComercial-SinDerivadas 3.0 España | * |
dc.rights.accessRights | info:eu-repo/semantics/openAccess | es_ES |
dc.rights.uri | http://creativecommons.org/licenses/by-nc-nd/3.0/es/ | * |
dc.subject | Energy-efficiency | es_ES |
dc.subject | Buildings | es_ES |
dc.title | Electrical consequences of large-scale replacement of metal halide by LED luminaires | es_ES |
dc.type | info:eu-repo/semantics/article | es_ES |
dc.type.version | info:eu-repo/semantics/acceptedVersion | es_ES |
Archivos
Bloque original
1 - 1 de 1
Cargando...
- Nombre:
- LRT-16-0034- versión aceptada.pdf
- Tamaño:
- 1.57 MB
- Formato:
- Adobe Portable Document Format
- Descripción:
Bloque de licencias
1 - 1 de 1
No hay miniatura disponible
- Nombre:
- license.txt
- Tamaño:
- 1.98 KB
- Formato:
- Item-specific license agreed upon to submission
- Descripción: