Please use this identifier to cite or link to this item: https://hdl.handle.net/10953/3340
Full metadata record
DC FieldValueLanguage
dc.contributor.authorDe La Torre Cruz, Juan-
dc.contributor.authorCañadas Quesada, Francisco Jesús-
dc.contributor.authorMartínez Muñoz, Damián-
dc.contributor.authorRuiz Reyes, Nicolás-
dc.contributor.authorGarcía Galán, Sebastián-
dc.contributor.authorCarabias Orti, Julio José-
dc.date.accessioned2024-10-30T09:45:01Z-
dc.date.available2024-10-30T09:45:01Z-
dc.date.issued2021-11-
dc.identifier.citationTorre-Cruz J., Cañadas-Quesada F.J., Martínez-Muñoz D., Ruiz-Reyes N., García-Galán S., Carabias-Orti J.J. An incremental algorithm based on multichannel non-negative matrix partial co-factorization for ambient denoising in auscultation. Applied Acoustics vol. 182, November 2021, 108229. https://doi.org/10.1016/j.apacoust.2021.108229es_ES
dc.identifier.issn0003-682Xes_ES
dc.identifier.otherhttps://doi.org/10.1016/j.apacoust.2021.108229es_ES
dc.identifier.urihttps://www.sciencedirect.com/science/article/abs/pii/S0003682X21003236?via%3Dihubes_ES
dc.identifier.urihttps://hdl.handle.net/10953/3340-
dc.description.abstractOne of the major current limitations in the diagnosis derived from auscultation remains the ambient noise surrounding the subject, which prevents successful auscultation. Therefore, it is essential to develop robust signal processing algorithms that can extract relevant clinical information from auscultated recordings analyzing in depth the acoustic environment in order to help the decision-making process made by physicians. The aim of this study is to implement a method to remove ambient noise in biomedical sounds captured in auscultation. We propose an incremental approach based on multichannel non-negative matrix partial co-factorization (NMPCF) for ambient denoising focusing on high noisy environment with a Signal-to-Noise Ratio (SNR) 6 5 dB. The first contribution applies NMPCF assuming that ambient noise can be modelled as repetitive sound events simultaneously found in two single-channel inputs captured by means of different recording devices. The second contribution proposes an incremental algorithm, based on the previous multichannel NMPCF, that refines the estimated biomedical spectrogram throughout a set of incremental stages by eliminating most of the ambient noise that was not removed in the previous stage at the expense of preserving most of the biomedical spectral content. The ambient denoising performance of the proposed method, compared to some of the most relevant state-of-the-art methods, has been evaluated using a set of recordings composed of biomedical sounds mixed with ambient noise that typically surrounds a medical consultation room to simulate high noisy environments with a SNR from -20 dB to -5 dB. In order to analyse the drop in denoising performance of the evaluated methods when the effect of the propagation of the patient’s body material and the acoustics of the room is considered, results have been obtained with and without taking these effects into account. Experimental results report that: (i) the performance drop suffered by the proposed method is lower compared to MSS and NLMS when considering the effect of the propagation of the patient’s body material and the acoustics of the room active; (ii) unlike what happens with MSS and NLMS, the proposed method shows a stable trend of the average SDR and SIR results regardless of the type of ambient noise and the SNR level evaluated; and (iii) a remarkable advantage of the proposed method is the high robustness of the acoustic quality of the estimated biomedical sounds when the two single-channel inputs suffer from a delay between them.es_ES
dc.description.sponsorshipThis work was supported by the Programa Operativo FEDER Andalucia 2014-2020 under project with reference 1257914 and the Ministry of Economy, Knowledge and University, Junta de Andalucia under Project P18-RT-1994.es_ES
dc.language.isoenges_ES
dc.publisherElsevieres_ES
dc.relation.ispartofApplied Acousticses_ES
dc.rightsAtribución-NoComercial-SinDerivadas 3.0 España*
dc.rights.urihttp://creativecommons.org/licenses/by-nc-nd/3.0/es/*
dc.subjectAuscultationes_ES
dc.subjectBiomedicales_ES
dc.subjectAmbient noisees_ES
dc.subjectNon-negative matrix partial co-factorizationes_ES
dc.subjectMultichanneles_ES
dc.subjectIncrementales_ES
dc.titleAn incremental algorithm based on multichannel non-negative matrix partial co-factorization for ambient denoising in auscultationes_ES
dc.typeinfo:eu-repo/semantics/articlees_ES
dc.rights.accessRightsinfo:eu-repo/semantics/openAccesses_ES
dc.type.versioninfo:eu-repo/semantics/acceptedVersiones_ES
Appears in Collections:DIT-Artículos

Files in This Item:
File Description SizeFormat 
RUJA_Revised_Manuscript_APAC-D-20-00596R1.pdf2,25 MBAdobe PDFView/Open


This item is protected by original copyright