RUJA: Repositorio Institucional de Producción Científica

 

Alternative Calibration of Cup Anemometers: A Way to Reduce the Uncertainty of Wind Power Density Estimation

Fecha

2019-04-30

Título de la revista

ISSN de la revista

Título del volumen

Editor

MDPI

Resumen

This study presents a procedure to reduce the uncertainty of wind power density estimations, which is useful to improve the energy production predictions of wind farms. Power density is usually determined from the wind speed measured by a cup anemometer and the air density value (conventional procedure). An alternative procedure based on wind speed and dynamic pressure estimations provided by a cup anemometer is proposed. The dynamic pressure is obtained by means of a calibration curve that relates the anemometer rotation frequency and the dynamic pressure measured by a Pitot tube. The quadratic regression, used to define the calibration curve, and its uncertainty are both detailed. A comparison between the alternative procedure and the conventional one points out the advantage of the proposed alternative since results show a high reduction of the indirect measurement uncertainty of wind power density.

Descripción

T1 Q1 (15/64 Instruments & Instrumentation, IF 2019= 3.275)

Palabras clave

wind speed sensor, cup anemometer, quadratic regression uncertainty, wind dynamic pressure, wind power density, wind tunnel, anemometer calibration, pitot tube

Citación

Guerrero-Villar, F.; Dorado-Vicente, R.; Medina-Sánchez, G.; Torres-Jiménez, E. Alternative Calibration of Cup Anemometers: A Way to Reduce the Uncertainty of Wind Power Density Estimation. Sensors 2019, 19, 2029. https://doi.org/10.3390/s19092029