Analysing the reciprocity law for UV-LEDs in water disinfection of Escherichia coli, Enterococcus faecalis and Clostridium perfringens
Fecha
2023
Título de la revista
ISSN de la revista
Título del volumen
Editor
MDPI
Resumen
The aim of this study is to verify the reciprocity law in the wastewater disinfection process using UV light. The optical power UV-LEDs used were 1.6 mW and 50 mW, and the wavelengths were 265 nm and 275 nm. E. coli, Enterococcus faecalis, and Clostridium perfringens were the three microorganisms analysed in the study. The results showed lower inactivation rates around 0.063–0.065 cm2/mJ for 265 nm and 0.047–0.049 cm2/mJ for 275 nm for the Clostridium perfringens compared with the other two bacteria. For E. coli and Enterococcus faecalis, the inactivation rate was almost identical; 0.28 and 0.21 cm2/mJ, respectively, using 265 nm wavelength. There was a slightly better inactivation performance using the medium-power 275 nm UV-LEDs of 0.39 cm2/mJ and 0.29 cm2/mJ for E. coli and Enterococcus faecalis, respectively, and 0.33 cm2/mJ and 0.26 cm2/mJ using the low-power 275 nm UV-LEDs. The analysed data justify the reciprocity law for UV-LEDs disinfection using 265 nm and 275 nm UV-LEDs with two optical powers of 1.6 mW and 50 mW.
Descripción
Palabras clave
Escherichia coli, Clostridium perfringens, Enterococcus faecalis, water treatment, disinfection, high-power UV light, light emitting diodes (LED), reciprocity
Citación
A. Kamel, M. Vivar, M. Fuentes, A. Palacios, ‘Analysing the reciprocity law for UV-LEDs in water disinfection of Escherichia coli, Enterococcus faecalis and Clostridium perfringens’, Water 15 (2023) issue 2, 352