RUJA: Repositorio Institucional de Producción Científica

 

Assessment of Tailings Ponds by a Combination of Electrical (ERT and IP) and Hydrochemical Techniques (Linares, Southern Spain)

dc.contributor.authorRey, Javier
dc.contributor.authorMartínez, Julián
dc.contributor.authorHidalgo, M. Carmen
dc.contributor.authorMendoza, Rosendo
dc.contributor.authorSandoval, Senen
dc.date.accessioned2024-04-17T07:04:15Z
dc.date.available2024-04-17T07:04:15Z
dc.date.issued2020-09-01
dc.description.abstractAccumulated mine waste in certain locations in the abandoned mining district of Linares-La Carolina (southern Spain) contain high levels of metals. Therefore, in recent years, many of these tailings ponds have been restored and sealed. This study assessed the efficacy of two geophysical techniques, electrical resistivity tomography (ERT) and induced polarisation (IP), combined with hydrochemical studies, as tools to image the effectiveness of the encapsulation. In the bedrock, ERT profiles distinguished a surficial layer of moderate-low resistivity values (below 80 Ω m), associated with alluvial sands or altered granite, and a deeper zone of high resistivity (up to 1000 Ω m) related to unaltered granite basement. Lateral changes in resistivity were identified inside the upper layer and downstream of the tailings pond. The IP profiles detected local anomalies in the chargeability values (up to 8 mV/V), unusual in granitic rocks. The locations with high chargeability also had low resistivity, which typically indicates the percolation of mining leachates in the underlying altered granites. Integration of geological and geochemical information confirmed this interpretation. This work verified that the combined use of ERT and IP methods were effective for monitoring ancient tailings ponds and for assessing tailings encapsulation.es_ES
dc.identifier.otherhttps://doi.org/10.1007/s10230-020-00709-3es_ES
dc.identifier.urihttps://hdl.handle.net/10953/2661
dc.language.isoenges_ES
dc.publisherSPRINGER LINKes_ES
dc.relation.ispartofMine Water and the Environment (2021), 40 (298–307)es_ES
dc.rights.accessRightsinfo:eu-repo/semantics/openAccesses_ES
dc.subjectMine wastees_ES
dc.subjectmetal(loid)es_ES
dc.subjectLeachate detectiones_ES
dc.subjectResistivityes_ES
dc.subjectChargeabilityes_ES
dc.subjectEnvironmental qualityes_ES
dc.titleAssessment of Tailings Ponds by a Combination of Electrical (ERT and IP) and Hydrochemical Techniques (Linares, Southern Spain)es_ES
dc.typeinfo:eu-repo/semantics/articlees_ES
dc.type.versioninfo:eu-repo/semantics/publishedVersiones_ES

Archivos

Bloque original

Mostrando 1 - 1 de 1
Cargando...
Miniatura
Nombre:
s10230-020-00709-3.pdf
Tamaño:
7.9 MB
Formato:
Adobe Portable Document Format
Descripción:

Bloque de licencias

Mostrando 1 - 1 de 1
No hay miniatura disponible
Nombre:
license.txt
Tamaño:
1.98 KB
Formato:
Item-specific license agreed upon to submission
Descripción:

Colecciones