Fernández-Fernández, EduardoGarcía-Loureiro, Antonio JesúsPérez-Higueras, PedroGómez-Vidal, Pedro2025-01-222025-01-222012-01-31E. F. Fernández, P. Pérez-Higueras, A. J. Garcia Loureiro, y P. G. Vidal, «Outdoor evaluation of concentrator photovoltaic systems modules from different manufacturers: First results and steps», Progress in Photovoltaics: Research and Applications, vol. 21, n.º 4, pp. 693-701, 2013, doi: 10.1002/PIP.1262.1062-7995, 1099-159X10.1002/PIP.1262https://hdl.handle.net/10953/4257For the behavior of concentrator photovoltaic systems technology under real conditions to be understood, different modules from different manufacturers were measured in a new research center in Jaén. The influence in the power and the efficiency of irradiation levels, air temperature, and the influence of air mass were under study for 6 months. Pmax shows a linear be- havior with direct normal irradiance, and efficiency was constant to a first approximation for a wide range of irradiance levels. The effect of air temperature was negligible for the temperatures under study. At the same time, efficiency shows a maximum around AM1.5 and decreases aside this point.engCC0 1.0 Universalhttp://creativecommons.org/publicdomain/zero/1.0/Concentrator photovoltaicOutdoor measuresCharacterizationOutdoor evaluation of concentrator photovoltaic systems modules from different manufacturers: first results and stepsinfo:eu-repo/semantics/articleinfo:eu-repo/semantics/openAccess